ABAC REFRIGERANT DRYERS



Today’s compressed air production process is not only a matter of producing air, but also of confirming with defined purity criteria. As humidity is a component of atmospheric air, it can be found in the compressed air distribution systems and the machines that use the compressed air in the form of condensate and/or vapour. ABAC provides refrigeration dryers to remove condensate and vapour so that dry compressed air is achieved and a continuous efficiency is preserved.




ABAC DRY SERIES REFRIGERATED AIR DRYERS
TYPE NOMINAL
CAPACITY
MAX
CAPACITY
MAX PRESSURE POWER POWER SUP. CONNECTION DIMENSIONS WEIGHT
Bar Psi Watt Volt/Hz/Phase Inch L x W x H (mm) Kg
DRY 20 333 350 16 232 130 230/50/1 3/4" 350X500X450 19
DRY 25 417 500 16 232 130 230/50/1 3/4" 350X500X450 19
DRY 45 750 900 16 232 164 230/50/1 3/4" 350X500X450 19
DRY 60 1.000 1.200 16 232 190 230/50/1 3/4" 350X500X450 20
DRY 85 1.417 1.650 16 232 266 230/50/1 3/4" 350X500X450 25
DRY 130 2.167 2.300 16 232 284 230/50/1 3/4" 350X500X450 27
DRY 165 2.750 3.000 16 188 609 230/50/1 1" 370X500X764 44
DRY 210 3.500 3.700 16 188 673 230/50/1 1" 370X500X764 44
DRY 250 4.167 4.500 16 188 793 230/50/1 1 1/2" 460X560X789 53
DRY 290 4.833 5.000 16 188 870 230/50/1 1 1/2" 460X560X789 60
DRY 360 6.000 6.500 16 188 1.072 230/50/1 1 1/2" 460X560X789 65
DRY 460 7.667 8.000 16 188 1.190 230/50/1 1 1/2" 580X590X899 80
DRY 530 8.833 9.500 16 188 1.446 230/50/1 1 1/2" 580X590X899 80
DRY 690 11.500 12.500 16 188 1.319 400/50/3 2" 735X898X962 128
DRY 830 13.833 15.000 16 188 1.631 400/50/3 2" 735X898X962 146
DRY 1040 17.333 18.500 16 188 1.889 400/50/3 2" 735X898X962 158
DRY 1260 21.000 22.000 16 188 2.110 400/50/3 2" 735X898X962 165


  • Refrigerant compressor driven by an electric motor, cooled using refrigerant fluid and protected against thermal overload.
  • Refrigerant condenser air-cooled and with a large exchange surface for high thermal exchange.
  • IP 54 motor-driven ventilator for the condenser cooling air flow.
  • Air/refrigerant evaporator with high thermal exchange and low leakage rates.
  • Condensate seperator, high-efficiency
  • Air-air heat exchanger with high thermal exchange and low load losses.
  • Hot gas bypass valve controls the refrigerant capacity under all load conditions preventing any formation of ice within the system
  • Digital Instrument Panel
  • Impurity filter for collecting any impurities to protect the system
  • Automatic discharge of condensate which is ecological and capable of preventing unwanted discharge of compressed air.

REFERENCE CONDITIONS:
Operating Pressure: 7 bar (100 psi)
Operating Temperature: 35 ºC
Room Temperature: 25 ºC
Pressure Dew Point: + 5 ºC ± 1 ºC
Available in different voltage and freqs

LIMIT CONDITIONS:
Operating Pressure: 16 bar (232 psi) DRY
20-130 and 13 bar (188 psi) DRY 165-1260
Operating Temperature: 55 ºC
Room Temperature: +5 ºC ; +45 ºC